C

Alarm of Power Supply (ECM)

Fanuc · Macro B CNC Programming

What does C mean?

A general alarm condition has occurred within the power supply unit of the Energy Charge Module (ECM). This indicates a problem with the main power input to the ECM or its internal power conversion circuitry.

Common Causes

  • Power supply unit (ECM) internal fault or failure.
  • Overcurrent condition detected in the ECM power stage.
  • Short circuit in the connected load to the ECM.
  • Voltage instability from the main power source affecting ECM.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Immediately stop the machine using the emergency stop button and open the external Main Circuit Contactor (MCC) of the Power supply.

  2. 2

    Check the incoming main power supply voltage and frequency to the αi PS or power supply module; ensure it is within the specified range (e.g., 200-240 VAC for 200V series, 400-480 VAC for 400V series).

  3. 3

    Inspect the circuit breakers and magnetic contactors connected to the power supply for tripping or damage (Section 3.1.3.10, page 95).

  4. 4

    Verify that the power supply wiring (Cable K1, Section 9.3.1.1, page 213) is securely connected and has the correct cross-sectional area.

  5. 5

    If an external power transformer is used, check its input and output voltages for correctness and stability (Section 3.1.3.7, page 89).