Internal fault (Specific range)
Danfoss · VLT AutomationDrive FC 301/302
What does 5376–6231 mean?
A general internal fault has occurred within a specific range of internal error codes. This indicates an unspecified internal hardware or software malfunction that requires specialized attention.
Common Causes
- Corrupted firmware on the control board or a specific option module (e.g., due to power fluctuation during update).
- Malfunction of internal power supply components on the control board or power board.
- Critical sensor failure or out-of-range reading on an internal component (e.g., DSP temperature).
- Data integrity error within internal memory (RAM/ROM) of the drive's CPU.
- Electromagnetic interference (EMI) disrupting internal communication buses (e.g., CAN bus) within the drive.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Record the full fault code (e.g., 5376, 5377) and contact technical support with the drive's serial number and firmware version.
- 2
Power cycle the frequency converter by switching off the main supply for at least 60 seconds.
- 3
Verify input voltage (e.g., L1-L2, L2-L3, L3-L1) is stable and within nameplate specifications (e.g., 400V +/-10%).
- 4
Check for loose connections on all internal ribbon cables and power connectors within the drive.
- 5
Attempt a factory reset of the drive parameters (e.g., using parameter 14-22, depending on drive model) after backing up current settings.