37

Communication Fault (Control Card - BMC2)

Danfoss · VLT 2800 Variable Speed Drive

What does 37 mean?

This fault indicates a communication error occurring between the drive's control card and the BMC2 component. Such an issue can prevent proper command execution or feedback, potentially leading to erratic drive behavior or complete shutdown. It points to a hardware or connection problem within the control circuitry.

Common Causes

  • Loose or damaged communication ribbon cable between the control card and BMC2 module, causing intermittent signal loss.
  • Electromagnetic interference (EMI) disrupting data packets on the internal communication bus, especially in noisy industrial environments.
  • Faulty BMC2 module hardware or corrupted firmware preventing it from responding to control card requests.
  • Damaged communication transceivers or processor on the main control card, inhibiting proper bus signaling.
  • Incorrect or incompatible firmware versions between the control card and BMC2 (e.g. BMC2 software version below minimum).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    1. Power down the drive, then verify the physical connection and seating of the ribbon cable between the control card and BMC2.

  2. 2

    2. Using an oscilloscope, measure the communication bus signals to identify noise spikes or data integrity issues (refer to bus specification).

  3. 3

    3. Update the firmware of the BMC2 module to the latest compatible version using the manufacturer's specified tool.

  4. 4

    4. Temporarily replace the BMC2 module with a known good unit to determine if the fault follows the module.

  5. 5

    5. If the fault persists after verifying BMC2 and cable, replace the main control card assembly.

Browse all codes in this manual (40)
Verified technical data. Last updated: March 2026

Related Faults

Source: Danfoss VLT 2800 Variable Speed Drive