Incorrect safety configuration
Bosch Rexroth · IndraDrive MPx02
What does F3144 mean?
This non-fatal safety error indicates that the safety configuration stored or loaded in the IndraDrive MPx02 is incorrect, inconsistent, or contains invalid settings. This prevents the safety functions from operating reliably or from being activated, leading to a safety stop.
Common Causes
- Incompatible safety parameters (e.g., parameter limits violated, contradictory settings).
- Configuration mismatch between the IndraDrive MPx02 and an external safety PLC.
- Corrupted safety parameter file or memory in the drive.
- Attempt to load a safety configuration not intended for the specific hardware or firmware version.
- Improper commissioning or modification of safety parameters.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Review the entire safety configuration of the IndraDrive MPx02, comparing it against the machine's safety design and validation documentation.
- 2
Load a previously saved, verified safety parameter set that is known to be correct for the application.
- 3
Check for firmware compatibility issues between the IndraDrive MPx02 and the safety configuration.
- 4
If an external safety PLC is used, verify that its safety program matches the safety configuration in the IndraDrive MPx02.
- 5
Perform a safety system re-commissioning, if necessary, ensuring all parameters are set correctly and consistently.