Safety related holding system: system error
Bosch Rexroth · IndraDrive MPx02
What does F3122 mean?
This non-fatal safety error indicates a general system error within the safety-related holding system of the IndraDrive MPx02. This system is responsible for safely holding an axis at a standstill, typically involving the motor holding brake, and a system error implies compromised reliability of this safety function.
Common Causes
- Internal fault within the IndraDrive MPx02's safety module responsible for the holding system.
- Faulty or incorrectly wired holding brake control circuit.
- Issues with the brake monitoring feedback signals (if present).
- Corrupted safety parameters related to the holding system.
- Insufficient or unstable power supply to the safety-related components.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Perform a complete power cycle of the IndraDrive MPx02 to reset the safety module.
- 2
Inspect all wiring related to the holding brake and its monitoring system for damage, loose connections, or incorrect termination.
- 3
Verify the brake control signals (e.g., 24VDC to brake) and feedback signals for proper voltage levels and timing.
- 4
Check relevant safety parameters in the IndraDrive MPx02 for consistency and valid configuration for the holding system.
- 5
If possible, test the holding brake independently to confirm its mechanical and electrical integrity.