F3112

Safety related reference missing

Bosch Rexroth · IndraDrive MPx02

What does F3112 mean?

This non-fatal safety technology error signifies that a critical safety-related reference is missing. This reference is essential for the IndraDrive MPx02 to perform safety functions correctly, potentially impacting safe motion or standstill monitoring.

Common Causes

  • Safety reference point for the axis has not been defined or was lost.
  • Encoder system (safety encoder) providing the reference is defective or disconnected.
  • Incorrect or incomplete commissioning of the safety functions requiring a reference.
  • Corruption of safety-related parameters in the IndraDrive MPx02's non-volatile memory.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Re-establish the safety reference point for the axis using the commissioning tools, ensuring it is properly saved.

  2. 2

    Verify the functionality and wiring of the safety encoder or absolute position feedback system.

  3. 3

    Check safety configuration parameters in the IndraDrive MPx02 for consistency and completeness, especially those related to position references.

  4. 4

    Perform a safety function test to confirm proper operation of all safety-related position monitoring.

  5. 5

    If the issue persists, consider reloading the last known good safety parameter set or re-commissioning the safety functions.

Browse all codes in this manual (99)
Verified technical data. Last updated: March 2026

Related Faults

Source: Bosch Rexroth IndraDrive MPx02