F2036

Excessive position feedback difference

Bosch Rexroth · IndraDrive C Drive Controllers

What does F2036 mean?

The difference between the expected and actual position feedback values is excessively large. This indicates a significant discrepancy in position tracking, potentially due to a feedback error or mechanical issue.

Common Causes

  • Loss or disturbance of position encoder signals.
  • Mechanical play, backlash, or slippage in the drive train.
  • Incorrect encoder scaling or gear ratio parameters.
  • Faulty encoder or drive feedback monitoring circuit.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect all encoder cabling and connections for security, damage, and proper shielding. Verify encoder power supply.

  2. 2

    Check the mechanical system for excessive backlash, loose couplings, or slippage in the belt/gear train.

  3. 3

    Verify the encoder scaling, gear ratio, and other position feedback parameters in the drive match the mechanical system.

  4. 4

    If using multiple encoders, compare their feedback values for consistency. Perform an encoder diagnostic test.

Browse all codes in this manual (66)
Verified technical data. Last updated: March 2026