42F3

Invalid coupling parameter for auxiliary axes

Beckhoff · TwinCAT 2 NC

What does 42F3 mean?

The coupling parameters configured for the auxiliary axes are inconsistent. These parameters define how auxiliary axes are linked or synchronized with other axes (e.g., master-slave, gearing), and an invalid setup will lead to improper synchronized motion, position errors, or loss of coordinated control.

Common Causes

  • Coupling factor (e.g., electronic gear ratio numerator/denominator, master-slave ratio) for an auxiliary axis is set to an invalid value (e.g., zero, negative).
  • Mismatch in the number of teeth or pitch for electronic gearing setup between the master axis and the auxiliary axis.
  • Referencing an invalid or non-existent master axis ID for an auxiliary axis configured in a slave role.
  • Inconsistent units or scaling factors used in coupling definitions between different axes, leading to incorrect synchronization.
  • PLC program attempting to establish a coupling with mathematically unresolvable parameters (e.g., division by zero in ratio calculation).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    1. Open the NC group or individual auxiliary axis configuration and review all coupling parameters (e.g., electronic gear numerator/denominator, master axis ID).

  2. 2

    2. Verify the coupling factor or gear ratio values are correct, positive, and non-zero.

  3. 3

    3. Ensure the specified master axis ID for any coupled auxiliary axis is valid and exists within the NC system.

  4. 4

    4. Check for consistency in units and scaling when defining coupling parameters (e.g., encoder increments per revolution, motor revolutions per unit).

  5. 5

    5. Save the updated configuration, download to the controller, and perform an NC reset before testing any coupled motion.

Browse all codes in this manual (60)