42

Phase VW Short

Allen-Bradley · PowerFlex 700

What does 42 mean?

Excessive current has been detected between output terminals V and W. This indicates a short circuit condition between these two motor phases or their connecting wiring, leading to very high currents and potential drive damage.

Common Causes

  • Short circuit detected between Phase V and Phase W.
  • Damaged insulation between Phase V and Phase W motor windings.
  • Faulty motor power cable with V and W shorted.
  • Internal short circuit in the drive's output stage.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the motor and drive output terminal wiring for a shorted condition between V and W.

  2. 2

    Replace the drive if wiring and motor are verified good.

Browse all codes in this manual (49)
Verified technical data. Last updated: March 2026

Related Faults