225

Warning during parameter application

ABB · Application Error ABB Motion Drives Error trouble shoo

What does 225 mean?

A warning occurred when downloading a parameter table to an e100 drive. This happens if a parameter in the table was not supported by the drive or that specific instance of the parameter did not exist. It can also be caused by an argument list having more than 2 parameters, a value list having more than 1 parameter, an incorrect value type, or downloading a parameter table generated for a different product configuration (e.g., MotiFlex e100 with resolver option vs. no option).

Common Causes

  • A parameter listed in the table is not supported by the specific MotiFlex e100 drive model or its installed options.
  • The argument list for a parameter update contains more than 2 parameters or an incorrect number of parameters.
  • The value list for a parameter update contains more than 1 parameter.
  • The data type of a parameter value in the table is incorrect.
  • The parameter table was generated for a MotiFlex e100 with a different hardware configuration or option set (e.g., resolver option vs. standard).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Review the parameter table (e.g., .ptx file) against the MotiFlex e100 drive's specific model and installed options to ensure all parameters are supported.

  2. 2

    Verify the structure of parameter updates: ensure argument lists do not exceed 2 parameters and value lists do not exceed 1 parameter.

  3. 3

    Check the data type of all parameter values in the table for correctness and consistency with the drive's parameter definitions.

  4. 4

    Ensure the parameter table was generated for the exact hardware revision and option configuration of the target MotiFlex e100 drive.

  5. 5

    If unsure, use Mint Workbench to generate a fresh parameter table from the target drive and then carefully compare it with the one causing the warning.

Browse all codes in this manual (58)
Verified technical data. Last updated: March 2026

Related Faults

Source: Application Error ABB Motion Drives Error trouble shoo
ABB 225 Warning during parameter application: Troubleshooti… | ErrorLib