Übersetzen...
CPF16

Clock Fault

Yaskawa · P1000

Was bedeutet CPF16 ?

An error has occurred with the internal clock circuit of the drive, which is essential for timing and synchronization of operations. This can cause timing inaccuracies and operational issues.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify stable input AC supply voltage at L1/R, L2/S, L3/T terminals against drive specifications.

  2. 2

    Verify DC bus voltage stability via the drive's display or accessible test points, ensuring no significant fluctuations.

  3. 3

    Inspect drive grounding connections and motor cable shielding for proper termination and integrity, ensuring minimal EMI interference.

  4. 4

    Backup current drive parameters and then perform a parameter initialization to factory defaults to rule out corrupted settings.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes