ACCUM
Accumulated Level Fault
Yaskawa · iQpump1000
Was bedeutet ACCUM ?
The total volume of water flow measured over time by the flow meter has exceeded the fault level setting. This fault is effective when P6-15 (Accumulated Behavior) is set to 2 (fault with manual monitor reset) or 3 (fault with automatic monitor reset).
Häufige Ursachen
- The accumulated level has exceeded the values set in P6-11 to P6-14.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Adjust the Accumulated Level fault characteristics in parameters P6-11 to P6-14 and P6-16.
- 2
Set parameter P6-15 (Accumulated Behavior) to control drive response.
- 3
Control auto-restart for this fault using P6-15 (Accumulated Behavior) and P6-05 (Flow Accumulation Reset).