Übersetzen...
UL4

Undertorque Detection 2

Yaskawa · GA500 Maintenance and Troubleshooting

Was bedeutet UL4 ?

This error indicates a mechanical problem, like a broken drive belt, or that the load parameters are incorrectly configured, resulting in the motor drawing less current than expected. The drive detects this when the output current drops below the threshold set in L6-05 for longer than L6-06. Persistent undertorque can signal a serious mechanical malfunction or inefficient operation.

Häufige Ursachen

  • Motor output torque falls below a secondary, lower minimum limit (P4-08).
  • Complete loss of load.
  • Motor is not engaged with the driven load.
  • Drive is commanding zero or minimal torque.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the machine for mechanical failures such as a broken pulley belt or shaft and address them immediately.

  2. 2

    Review and fine-tune the L6-05 [Torque Detection Level 2] and L6-06 [Torque Detection Time 2] parameters to ensure they are appropriate for the application's load.

  3. 3

    Execute a Fault Reset to clear the error once the fault condition is eliminated.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Yaskawa GA500 Maintenance and Troubleshooting