Übersetzen...
7001

Fault sensor interior temperature

SMA · SUNNY TRIPOWER X Solar Inverter

Was bedeutet 7001 ?

An internal temperature sensor within the inverter is defective. This fault causes the inverter to interrupt its feed-in operation to prevent potential overheating or damage due to inaccurate temperature monitoring.

Häufige Ursachen

  • Defective internal temperature sensor.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the inverter's ventilation openings and cooling fins for obstructions or excessive dust accumulation.

  2. 2

    Verify the ambient temperature surrounding the inverter is within the manufacturer's specified operating range.

  3. 3

    Access the inverter's diagnostic interface to verify current internal temperature readings and check the event log for related warnings or fault patterns.

  4. 4

    Perform a controlled shutdown and restart of the inverter to rule out transient software or communication errors.

  5. 5

    Verify the inverter's firmware version is current and compatible with the hardware, updating if a newer version addresses sensor-related issues.

Alle Codes in diesem Handbuch durchsuchen (9)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: SMA SUNNY TRIPOWER X Solar Inverter