7901
Reverse current has occurred in PV array
SMA · SUNNY CENTRAL 500CP XT / 630CP XT Solar Inverter
Was bedeutet 7901 ?
Reverse current has been detected in the PV array. This condition can damage the PV modules or the inverter. The inverter will shut down for 1 minute and reset automatically on day change.
Häufige Ursachen
- Faulty PV modules.
- Shading or mismatch conditions causing reverse bias in certain modules.
- Wiring errors.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Identify and isolate the affected PV string or modules.
- 2
Check for any shading issues on the PV array.
- 3
Contact the SMA Service Line for further diagnosis.