501
Grid fault (Frequency Out of Range)
SMA · Sunny Boy Solar Inverter
Was bedeutet 501 ?
The power frequency is not within the permissible range, causing the inverter to disconnect from the utility grid. Frequent occurrences suggest a persistent issue with grid frequency stability.
Häufige Ursachen
- Power frequency is outside the permissible operating range.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
If possible, check the power frequency and observe how often fluctuations occur.
- 2
If fluctuations occur frequently and this message is displayed often, contact the grid operator and request approval to change the operating parameters of the inverter.
- 3
If the grid operator gives approval, discuss any changes to the operating parameters with the Service.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026