Übersetzen...
3901/3902
Waiting for DC start conditions > Start cond. not met
SMA · Sunny Boy Solar Inverter
Was bedeutet 3901/3902 ?
The necessary feed-in conditions for the utility grid have not yet been fulfilled, preventing the inverter from starting operation. This is often related to environmental conditions or initial setup parameters.
Häufige Ursachen
- PV array is covered by snow or otherwise shaded, reducing power output.
- Insufficient solar irradiation to meet minimum operating thresholds.
- The voltage limit for starting grid feed-in is set too high (parameter `Critical voltage to start feed-in`).
- PV array is incorrectly rated for the inverter's start-up requirements.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Ensure that the PV array is not covered by snow or otherwise shaded.
- 2
Wait for higher solar irradiation levels.
- 3
If this message is displayed frequently in the morning, increase the voltage limit for starting grid feed-in by changing the parameter `Critical voltage to start feed-in`.
- 4
If this message is displayed frequently with medium irradiation, ensure that the PV array is correctly rated for the inverter.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: SMA Sunny Boy Solar Inverter