Übersetzen...
EarthCurMax-B

BFR-Related Earth Current Exceeds Tolerable Range

SMA · SUNNY BOY 5000US-8000US Solar Inverter

Was bedeutet EarthCurMax-B ?

The earth current between the PV+ conductor and ground (GND), monitored by the BFR (Betriebsführungsrechner), has exceeded its acceptable operating range in the Sunny Boy SB50US-80US-IUS094030. This indicates a ground fault in the PV array. The inverter will disconnect from the grid.

Häufige Ursachen

  • Ground fault in the PV array detected by the BFR.
  • Ground fault current exceeding 1 Amp.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Switch off the external DC disconnect to the Sunny Boy SB50US-80US-IUS094030.

  2. 2

    Switch off the main AC circuit breaker connecting the Sunny Boy to the grid.

  3. 3

    Troubleshoot the PV array to locate and clear the ground fault.

  4. 4

    Manually clear the ground fault error on the user interface display after correction.

Alle Codes in diesem Handbuch durchsuchen (23)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: SMA SUNNY BOY 5000US-8000US Solar Inverter
SMA EarthCurMax-B (BFR-Related Earth Current Exceeds Tolera… | ErrorLib