Übersetzen...
F40003

Fault at DRIVE-CLiQ socket X103

Siemens · SINAMICS S120/S150 Reference List

Was bedeutet F40003 ?

A general fault has been detected at the drive object connected to the DRIVE-CLiQ socket X103. The fault value (r0949) provides information about the specific underlying fault that first occurred for this drive object. This fault requires immediate acknowledgment.

Häufige Ursachen

  • Damaged or improperly shielded DRIVE-CLiQ cable between the drive and the component connected to socket X103, leading to data corruption or signal loss.
  • Loose or corroded contact pins within the DRIVE-CLiQ connector at socket X103, preventing reliable communication.
  • The connected DRIVE-CLiQ component (e.g., motor module, sensor module, motor with integrated encoder) at X103 is faulty or has incompatible firmware.
  • Insufficient or intermittent 24VDC supply to the connected DRIVE-CLiQ component, causing communication errors or device malfunction.
  • Incorrect DRIVE-CLiQ parameterization (e.g., p0940 (Component type), p0941 (Topology ID)) for the device connected to X103, preventing proper initialization.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Power down the drive, then visually inspect the entire length of the DRIVE-CLiQ cable connected to socket X103 for physical damage, sharp bends, or cuts. Verify cable shielding is intact and properly grounded at both ends.

  2. 2

    Power down the drive, then firmly reseat the DRIVE-CLiQ connector at socket X103 on the drive and at the connected component's port. Ensure the latching mechanism is fully engaged.

  3. 3

    Measure the 24VDC supply voltage at the power terminals of the component connected via X103 (if applicable) while the system is powered on, ensuring it remains within +/-10% of 24VDC.

  4. 4

    Check drive parameters r0940 (Component type) and r0941 (Topology ID) for the component at X103 and compare them with the actual component type and expected topology. Reconfigure p0940 if incorrect.

  5. 5

    If the fault persists, replace the DRIVE-CLiQ cable connected to X103 with a known good, identical length cable to rule out cable failure.

  6. 6

    If the fault still persists after verifying cable and power, temporarily replace the DRIVE-CLiQ component connected to X103 with a known good, compatible unit to isolate a component hardware fault.

Alle Codes in diesem Handbuch durchsuchen (32)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Siemens SINAMICS S120/S150 Reference List