Expected fault during component replacement
Siemens · SINAMICS G120
Was bedeutet F01680 ?
This fault is part of a group (F01641, F01650, F01680, F30680) that is expected to occur temporarily during specific corrective maintenance procedures, such as replacing a Control Unit or the entire inverter. It does not indicate a persistent problem if the full replacement and recommissioning steps are followed. The risk is negligible if acknowledged as part of the procedure.
Häufige Ursachen
- A Control Unit (CU) or Power Module (PM) has been replaced, and the system is detecting hardware differences during initial power-up.
- Firmware version mismatch between a newly installed component and existing system components, causing an initialization error.
- Parameter inconsistencies or missing data after a component replacement, especially if parameters were not backed up and restored.
- Incorrect installation or seating of a newly replaced module (e.g., loose connections on the Control Unit).
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
1. Confirm that the component replacement (e.g., Control Unit, Power Module) was completed successfully and all connections are secure.
- 2
2. Perform a parameter reset to factory defaults (e.g., p0010 = 30, p0970 = 1) if parameter backup/restore was not performed prior to replacement.
- 3
3. Download the correct parameter set from a backup (if available) to the newly installed component using commissioning software (e.g., STARTER, TIA Portal).
- 4
4. Execute a firmware update on the replaced component to match the system's current firmware version, if necessary.
- 5
5. Cycle power to the drive system after ensuring all modules are correctly installed and parameters are loaded.