Encoder 2: Absolute encoder EnDat, internal fault/error
Siemens · DAsl Diagnostics and Alarms
Was bedeutet 232111 ?
The EnDat encoder's internal fault word has set fault bits, indicating a problem with the encoder's internal operation. This could relate to the lighting system, signal amplitude, position value accuracy, or issues with the encoder's power supply (over/undervoltage, overcurrent). The exact fault is detailed in r0949, where each bit represents a specific cause, ranging from a failed lighting system to encoder power supply issues.
Häufige Ursachen
- Internal component failure within the secondary EnDat encoder (Encoder 2), such as degradation of the optical system or sensor array.
- Low signal amplitude from Encoder 2 detected by its internal diagnostic, potentially due to internal contamination, aging components, or mechanical issues.
- Checksum errors or inconsistent position data reported by Encoder 2, indicating internal processing errors or data corruption.
- Operating temperature of Encoder 2 exceeding its specified thermal limits, leading to internal component stress and failure.
- Intermittent or unstable power supply to Encoder 2, causing unreliable internal operation and communication errors.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Access the drive's diagnostic buffer (r0949 or relevant encoder diagnostic parameter) to determine the specific fault bits reported by Encoder 2 (EnDat fault word).
- 2
Power cycle the machine and observe if the fault clears for Encoder 2; transient internal errors can sometimes be reset by a system restart.
- 3
Verify the supply voltage to Encoder 2 (e.g., at its connector X21) meets the manufacturer's specification (e.g., 5VDC or 24VDC) using a multimeter.
- 4
Inspect the mounting of Encoder 2 and the motor for excessive vibration or mechanical misalignment that could impact encoder longevity and signal quality.
- 5
If the fault persists after power cycling and supply voltage verification, plan for replacement of the secondary EnDat absolute encoder (Encoder 2).