97

Copy error (Parameter transmission error)

SEW Eurodrive · MOVIMOT MM..D With AC Motor DRS

Was bedeutet 97 ?

An error occurred during the copying process of parameters (also referred to as parameter transmission error), potentially due to interruption of the connection or power supply during data transfer from a keypad or PC.

Häufige Ursachen

  • Disconnecting the DBG keypad or the PC during the parameter copying process
  • Switching the 24 V supply voltage off and on during the parameter copying process

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Load the factory setting from the DBG keypad or MOVITOOLS® MotionStudio software before acknowledging the error

  2. 2

    Load the complete data record from the DBG keypad or MOVITOOLS® MotionStudio software before acknowledging the error