F14-0

Encoder not connected, defective encoder, defective encoder cable

SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive

Was bedeutet F14-0 ?

The encoder or its cable is either not connected correctly, has a short circuit or broken wire, or the encoder unit itself is defective. It may also occur if 2 inverters are connected via X14 and P505 is set to YES, causing SubC 27.

Häufige Ursachen

  • Encoder is not physically connected to the device.
  • Encoder cable is damaged or has a broken connection.
  • The encoder itself is defective and not functioning.
  • Incorrect encoder type selected in configuration.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check encoder cable and shield for correct connection, short circuit and broken wire.