F109-42
Plausibility fault incorrect acceleration
SEW Eurodrive · MOVIDRIVE MDX60B/61B Variable Speed Drive
Was bedeutet F109-42 ?
The current acceleration has exceeded the configured maximum acceleration limit. This indicates a discrepancy between actual motor dynamics and the set parameters, potentially due to incorrect configuration or mechanical issues.
Häufige Ursachen
- Measured acceleration value exceeds plausible limits.
- Encoder velocity or position data indicates unrealistic acceleration.
- Incorrect configuration of acceleration monitoring parameters.
- Sensor malfunction causing erratic acceleration readings.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the configuration (encoder screen: max. set speed).
- 2
Analyze the speed/acceleration profile using the SCOPE function.