43

RS485 Timeout

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

Was bedeutet 43 ?

Rapid stop because the RS485 communication connection between the inverter and the PC has been interrupted, leading to a communication timeout. The drive loses its control link to the PC.

Häufige Ursachen

  • Communication timeout on the RS485 serial interface.
  • Slave device on RS485 is not responding.
  • RS485 wiring issues (e.g., termination, noise).
  • Incorrect baud rate or communication protocol settings.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the RS485 connection cable and interfaces between the inverter and the PC for integrity.