Emergency Stop Timeout
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Was bedeutet 30 ?
Immediate switch-off because the drive is overloaded or the emergency stop ramp is configured too short. The drive is unable to decelerate to a stop within the programmed emergency stop time.
Häufige Ursachen
- Emergency stop signal not received within the expected timeframe.
- Emergency stop button remains pressed after acknowledgment.
- Faulty wiring to the emergency stop input.
- E-stop signal lost due to communication error.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Review project planning parameters for appropriate drive sizing and emergency stop settings.
- 2
Extend the emergency stop ramp time to allow for a longer deceleration period.