Übersetzen...
28
Fieldbus Timeout
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Was bedeutet 28 ?
Rapid stop caused by a loss of communication between the master and slave devices within the configured response monitoring time on the fieldbus. This signifies a disruption in fieldbus data exchange.
Häufige Ursachen
- Communication with a fieldbus device has been interrupted.
- Slave device is not responding on the fieldbus network.
- Incorrect fieldbus address configuration.
- Fieldbus network cable issue (e.g., termination, break).
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the communications routine and logic of the fieldbus master controller.
- 2
Extend the fieldbus timeout time (P819) or, if appropriate for the application, temporarily deactivate monitoring to diagnose.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)