14
Encoder Error
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Was bedeutet 14 ?
Immediate switch-off due to an issue with the encoder feedback, such as an incorrectly connected encoder cable or shield, a short circuit or broken wire within the cable, or a defective encoder unit itself. This prevents accurate speed and position feedback.
Häufige Ursachen
- Encoder feedback signal is lost, corrupted, or inconsistent.
- Faulty encoder on the motor.
- Encoder cable disconnected or damaged, interrupting communication.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the encoder cable and shield for correct physical connection.
- 2
Inspect the encoder cable for any short circuits between conductors or to ground.
- 3
Inspect the encoder cable for any broken wires.
- 4
If wiring is correct, replace the encoder if it is confirmed defective.