Invalid Axis Selection

SEW Eurodrive · MOVI-PLC SyncCrane Application

Was bedeutet FF0202h ?

This fault occurs when an invalid axis number is selected for control. For group control, Process Output Data word PO3 must be set to 99. For single axis control, PO3 must be set to a value between 1 and 8, corresponding to the specific axis.

Häufige Ursachen

  • An invalid axis identifier was used in a command or configuration.
  • Attempting to control an axis that has not been properly initialized or configured.
  • Selection of a non-existent or disabled axis in a multi-axis system.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the value of process output data word PO3 (Axis number selection) — ensure it is 99 for group control.

  2. 2

    Verify the value of process output data word PO3 (Axis number selection) — ensure it is a value between 1 and 8 for single-axis control.