36

Option missing

SEW Eurodrive · MCBSM

Was bedeutet 36 ?

Immediate switch-off with inhibit. This fault occurs if an incorrect option card is used, the setpoint/control signal source or operating mode is not permitted for the option card, or a required option is entirely missing. This prevents proper system functionality and operation, necessitating a restart after correction.

Häufige Ursachen

  • A required option module is not physically installed or detected.
  • Option slot is empty where a module is expected by configuration.
  • Faulty connection of the option module.
  • Configuration parameter (e.g., P1-02) expects an option that is not present.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Use the correct option card compatible with the unit.

  2. 2

    Set the correct setpoint source, control signal source, or operating mode according to the application.

  3. 3

    Check parameters P120 and P121 for FBG11B, and P120 and P642 for FIO12B, to ensure required options are present and correctly configured.