Übersetzen...
0C8A
Error in outgoing MFI interface (OUT1)
SEW Eurodrive · Drives
Was bedeutet 0C8A ?
The outgoing MFI interface (OUT1) was activated even though no station is connected or was configured in the master. This indicates a mismatch between the physical setup and the INTERBUS master configuration.
Häufige Ursachen
- No station physically connected to the outgoing interface OUT1.
- Outgoing interface OUT1 not configured in the INTERBUS master.
- Incorrect setting of DIP switch 6 (NEXT/END) on the MFI.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the setting of DIP switch 6 (NEXT/END) on the MFI. If the MFI is the last station in the bus segment, this switch must be set to END.
- 2
Verify that a station is physically connected to OUT1 if it is enabled.
- 3
Check the INTERBUS master configuration to ensure OUT1 is correctly configured for connected stations.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: SEW Eurodrive Drives