Übersetzen...
01

Overcurrent in Output Stage

SEW Eurodrive · MOVIMOT® MM..D with AC Motor DT/DV / Operating Instruc

Was bedeutet 01 ?

This fault indicates an excessive current flow detected in the inverter's output stage, leading to a motor stop. This typically signals a short circuit condition on the inverter's output or within the motor winding, which can damage the inverter's power components.

Häufige Ursachen

  • Short circuit on inverter output.
  • Short circuit in the connection between inverter output and motor.
  • Short circuit within the motor winding.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the connection between the inverter output and the motor for short circuits.

  2. 2

    Check the motor winding for short circuits.

  3. 3

    Reset the fault by switching off and then switching on the DC 24V supply voltage.

  4. 4

    Reset the error via the error reset function.

Alle Codes in diesem Handbuch durchsuchen (23)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: MOVIMOT® MM..D with AC Motor DT/DV / Operating Instruc