DW not closed

DCS DW Not Closed Error

Otis · GAA21750AK3 Service Tool

Was bedeutet DW not closed ?

During the Door Check Sequence (DCS), the DW (Door Closed) safety contact at the specified level did not register as closed when required. This indicates that the elevator door is not fully secured, posing a safety risk and preventing normal operation of the OTIS 2000 Controllers MCS120/MCS220.

Häufige Ursachen

  • Elevator door not fully closed.
  • Misaligned or faulty DW safety contact switch.
  • Debris preventing the door from fully latching or closing.
  • Wiring issue in the DW safety circuit.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Identify the specific level where the DW not closed error occurred from the GAA21750AK3 service tool.

  2. 2

    Visually confirm the door is fully closed and latched.

  3. 3

    Inspect the DW safety contact for physical damage, misalignment, or signs of wear.

  4. 4

    Measure continuity across the DW contact terminals when the door is closed, expecting a closed circuit.

Alle Codes in diesem Handbuch durchsuchen (15)