Both 1LS and 2LS Operated
Otis · GAA21750AK3 Service Tool
Was bedeutet >1LS + 2LS ! ?
This blinking event message indicates that both Limit Switch 1 (1LS) and Limit Switch 2 (2LS) are simultaneously in an operated state, blocking elevator movement. This condition is typically indicative of an abnormal car position or a wiring fault within the OTIS 2000 Controllers MCS120/MCS220 system.
Häufige Ursachen
- Incorrect car positioning leading to simultaneous actuation of both limit switches.
- Short circuit or cross-wiring in the limit switch circuits.
- Mechanical fault causing both switches to remain in an operated state.
- Faulty individual limit switches, causing one or both to be stuck in an actuated position.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the elevator car's actual position relative to the limit switches 1LS and 2LS.
- 2
Inspect 1LS and 2LS for physical damage or simultaneous mechanical actuation.
- 3
Check wiring for 1LS and 2LS circuits for short circuits or incorrect connections.
- 4
Measure the individual state of each limit switch contact to identify if one is stuck in an operated position.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026