Übersetzen...
F901

Armature Circuit Open (Loop Confirm)

Otis · DSD 412 DC Elevator Drive

Was bedeutet F901 ?

This fault is triggered if the motor armature circuit is not closed before the "Loop Confirm" signal asserts, preventing the drive from establishing a closed current path to the motor. It indicates a disconnection that inhibits motor operation and often occurs during the drive's startup sequence.

Häufige Ursachen

  • Disconnection or damage in the motor armature power cabling between the drive and the motor.
  • Failure of the main armature contactor to close properly, leaving the circuit open.
  • Issues with the "Loop Confirm" input signaling closure prematurely when the armature path is still open.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    De-energize the drive and visually inspect all motor armature power connections for looseness or damage.

  2. 2

    Perform a continuity check on the motor armature power cables and through the main armature contactor's power contacts.

  3. 3

    Confirm that the "Loop Confirm" input signal accurately reflects the actual closed state of the armature circuit.

  4. 4

    Verify the motor's armature winding resistance against manufacturer specifications.

Alle Codes in diesem Handbuch durchsuchen (48)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Otis DSD 412 DC Elevator Drive