Übersetzen...
911
SHORTED SCRS/DOUBLER FAULT
Otis · DSD 412 DC Elevator Drive
Was bedeutet 911 ?
One of the SCR/Doubler packs has a short circuit between the SCRs. This condition is checked only upon request through the PCU #998 Diagnostics CDU function. The optional handheld PCDU can also identify the specific SCR pair that is faulty. A DSD Power Down is required.
Häufige Ursachen
- A short circuit has occurred within an SCR/Doubler pack.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Initiate a DSD Power Down for the drive.
- 2
Run the PCU #998 Diagnostics CDU function to identify the specific shorted SCR/Doubler pack.
- 3
If available, use the optional handheld PCDU to identify the exact shorted SCR pair.
- 4
Replace the identified shorted SCR/Doubler pack.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Otis DSD 412 DC Elevator Drive