Too Hot
Refrigeration Too Hot
Otis · 400 Elevator
Was bedeutet Too Hot ?
Indicates that the refrigeration temperature is 1.5º C above the compressor cut-in setting, suggesting the unit is not cooling sufficiently. This can compromise product integrity and safety.
Häufige Ursachen
- Refrigeration system failure to cool effectively.
- High ambient temperature affecting cooling performance.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the accuracy of the refrigeration temperature sensor against a calibrated reference thermometer.
- 2
Measure the supply voltage at the compressor input terminals and verify compressor operation (audible running, vibration).
- 3
Inspect condenser and evaporator coils for cleanliness, obstructions, and verify proper airflow from fans.
- 4
Check the refrigeration unit's control parameters, specifically the compressor cut-in/cut-out temperature setpoints, against documentation.