Changer Communication Loss
Otis · 400 Elevator
Was bedeutet Changer Comm ?
Indicates no communication with the coin changer for more than 2 seconds. This issue prevents coin acceptance and dispensing, rendering the changer inoperable.
Häufige Ursachen
- Loss of communication between the controller and the coin changer.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the supply voltage to the coin changer module's power input terminals is stable and within the specified operating range.
- 2
Inspect all communication cables and connectors between the main elevator controller and the coin changer for physical damage, proper seating, and secure connections.
- 3
Check the communication bus wiring for correct polarity, continuity, and absence of shorts or opens using an appropriate diagnostic tool.
- 4
Verify the communication parameters (e.g., baud rate, parity, data bits, stop bits, device ID/address) configured in the elevator controller match those configured in the coin changer module.