548E hex
Auxiliary and Slave Defined as Same Axis
Omron · NJ/NX-series Motion Control
Was bedeutet 548E hex ?
This minor fault occurs when the Auxiliary Axis and Slave Axis are configured to be the same axis during an axis command instruction. This configuration results in an execution condition error, affecting combined axis operations.
Häufige Ursachen
- The Axis Variable specified for Auxiliary and Slave are identical in the instruction call.
- Incorrect axis assignment during the setup of the motion control instruction.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the Axis Variable specified for Auxiliary in the instruction is distinct from the Axis Variable specified for Slave.
- 2
Check the Axis Basic Settings in Sysmac Studio to ensure unique axis assignments for Auxiliary and Slave functions.