54013781 hex

Process Data Object Setting Missing

Omron · NJ/NX-series Machine Automation Controller

Was bedeutet 54013781 hex ?

The PDO mapping for CNC instructions is incorrect. This means required Process Data Objects are not properly configured or the instruction is used with an incompatible device.

Häufige Ursachen

  • The PDOs that are required for the CNC instruction are not mapped.
  • The relevant instruction was executed for a device that does not have an object that supports the instruction.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the PDO mapping configuration for the CNC instructions within the Sysmac Studio project, ensuring all required Process Data Objects are correctly assigned and enabled.

  2. 2

    Check the compatibility of the connected EtherCAT slave device(s) with the specific CNC instructions being utilized, referencing Omron and device manuals.

  3. 3

    Inspect the EtherCAT slave device parameters and settings in Sysmac Studio to ensure they align with the configured PDOs and CNC instruction requirements.

  4. 4

    Verify the EtherCAT network configuration, including slave node addresses and connection status, to ensure proper communication for PDO transfer.