Was bedeutet 18230000 hex ?

The absolute encoder detected an error in its multi-rotation counting function. This is often caused by temporary issues like vibration, impact, condensation, or an internal encoder failure, leading to incorrect absolute position.

Häufige Ursachen

  • A temporary error occurred in the encoder multi-rotation detection function due to vibration, impact, or condensation.
  • Encoder failure.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the encoder for signs of physical impact, vibration, or moisture (condensation).

  2. 2

    Ensure the encoder is securely mounted and isolated from excessive vibration.

  3. 3

    Check environmental conditions (temperature, humidity) around the encoder.