Übersetzen...
Ud (100)
Overheat Protection (Outdoor Pipe)
Mitsubishi Electric · PUZ-HA30/36NHA4 Outdoor Unit
Was bedeutet Ud (100) ?
The outdoor pipe thermistor (TH2) detects a temperature of 70°C [158°F] or more during compressor operation. This indicates either a defective outdoor fan (fan motor), a short cycle of the outdoor unit during cooling operation, or a faulty outdoor pipe thermistor (TH2).
Häufige Ursachen
- Outdoor pipe temperature has exceeded the overheat protection threshold (Ud code).
- Insufficient refrigerant flow causing localized overheating.
- Blockage in the outdoor unit's heat exchanger or piping.
- Ambient temperature is too high, leading to poor heat dissipation.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the outdoor unit air passage for obstructions.
- 2
Turn the power off and on again to clear the error code. If U9 is subsequently displayed, follow the U9 troubleshooting procedures.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Mitsubishi Electric PUZ-HA30/36NHA4 Outdoor Unit