MissingProcess- Gas
No process gas!
Kuka · LaserTech 3.1
Was bedeutet MissingProcess- Gas ?
The required process gas supply is either off, depleted, or not reaching the laser system at the required pressure. This prevents proper laser operation and affects process quality.
Häufige Ursachen
- Process gas supply is interrupted or absent.
- Low pressure detected in the process gas line.
- Gas flow sensor failure or blockage.
- Incorrect gas mixture detected.
- Gas cylinder depleted or valve closed.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the process gas supply tank level and ensure all gas valves are open.
- 2
Check the gas pressure at the laser system's input manifold.
- 3
Acknowledge the message on the robot controller HMI.
- 4
Resume or restart the program.