LaserAllocation- Avoided
Laser allocation denied
Kuka · LaserTech 3.1
Was bedeutet LaserAllocation- Avoided ?
The system's request to allocate the laser has been denied. This can happen if the laser is already allocated to a different station, is in manual mode, or if another active error prevents allocation.
Häufige Ursachen
- Request to use a laser source was rejected by the system.
- Laser resource is currently unavailable or allocated to another task.
- System logic prevented laser activation due to safety or operational constraints.
- The intended laser process is not permitted under current conditions.
- Configuration error preventing laser resource assignment.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify if the laser is currently allocated to a different workstation or process; release if necessary.
- 2
Confirm the laser is not in manual mode (refer to 'LsrInManual-Mode' for resolution).
- 3
Check for other active laser errors that might prevent allocation and resolve them.