Positioning monitoring {(Axis number)}
Kuka · KSS 8.3 System Software
Was bedeutet 1105 ?
Positioning monitoring has been triggered for a specific axis. This fault indicates that the axis is not accurately reaching its target position within the expected tolerances or time. This is a regular monitoring function that may be deactivated in torque mode to accommodate larger position deviations inherent to that operational state.
Häufige Ursachen
- The axis position monitoring function has detected an anomaly.
- Deviation from the expected position range for {(Axis number)} during a move or dwell.
- Positional accuracy has fallen outside the allowed tolerance on {(Axis number)}.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Identify the specific axis number mentioned in the error message.
- 2
Check the mechanical integrity of the axis, looking for excessive play in gears, backlash, or loose connections that could affect positioning accuracy.
- 3
Review the motion program and path planning for the axis, ensuring target positions are reachable and motion commands are appropriate.
- 4
If operating in torque mode, verify that `SET_TORQUE_LIMITS(..., monitor #off)` is configured if the regular positioning monitoring is intended to be deactivated.