invalid optional Slave Configuration
Invalid Optional Slave Configuration
Kuka · KR C4 PROFIBUS
Was bedeutet invalid optional Slave Configuration ?
The file 'ecat_PBM_Gateway.xml', which contains the optional slave configuration, is faulty. This prevents correct initialization of optional slave devices on the PROFIBUS.
Häufige Ursachen
- Configuration parameters for optional slave devices are incorrect.
- Slave device addresses or types are not compatible with gateway settings.
- Invalid data types or ranges specified for optional slave configuration.
- Communication error with an optional slave device during configuration.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Correct the 'ecat_PBM_Gateway.xml' file for any errors.
- 2
Reconfigure the bus after correcting the file.