Übersetzen...
invalid Gateway Error-Byte Config

Invalid Gateway Error-Byte Configuration

Kuka · KR C4 PROFIBUS

Was bedeutet invalid Gateway Error-Byte Config ?

The configuration of the error status bytes for the devices does not match the overall bus configuration. This suggests a mismatch in how error conditions are reported or interpreted.

Häufige Ursachen

  • Error-byte configuration in the gateway is invalid or not supported.
  • Incorrect bitmask or value set for error reporting in the gateway.
  • Firmware mismatch between gateway and configuration tool.
  • Attempting to configure error reporting beyond device capabilities.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the bus configuration in WorkVisual for consistency in error byte settings and correct if necessary.

  2. 2

    Reconfigure the bus after correcting the configuration.

Alle Codes in diesem Handbuch durchsuchen (19)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes