26131
Intermediate circuit charging failed, KPP/KSP (axis)
Kuka · KR C4 extended
Was bedeutet 26131 ?
This fault indicates that the intermediate DC link circuit failed to charge properly during power-up or initialization. This prevents the drive from starting or operating, pointing to a fundamental issue in the power supply path or the charging components.
Häufige Ursachen
- Faulty intermediate circuit cabling.
- Malfunction in the KSP module's charging circuit.
- Malfunction in the KPP module's charging circuit.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check intermediate circuit cabling for continuity and proper connections.
- 2
Reinitialize the drive bus: Power Off / Power On.
- 3
Check KSP module for faults related to charging.
- 4
Check KPP module for faults related to charging.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026