Übersetzen...
26050

Fault in brake resistor, KPP/KSP (axis)

Kuka · KR C4 extended

Was bedeutet 26050 ?

The KPP module has detected an error in the ballast circuit, which typically includes the brake resistor. This indicates an issue with the energy dissipation components, potentially leading to overvoltage conditions if braking energy cannot be properly absorbed.

Häufige Ursachen

  • Ballast resistor fault.
  • Cabling between KPP and ballast resistor is damaged or improperly connected.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the ballast resistor for damage or overheating.

  2. 2

    Check cabling between the KPP and the ballast resistor for damage and correct connections.

  3. 3

    Reinitialize the drive bus: Power Off / Power On.

  4. 4

    Check the KPP module.

Alle Codes in diesem Handbuch durchsuchen (35)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes