26033
Ground fault, KPP/KSP (axis)
Kuka · KR C4 extended
Was bedeutet 26033 ?
An overcurrent condition, specifically a ground fault, has occurred in the power unit of the KPP or KSP module for a specific axis. This indicates insulation breakdown or a direct short to ground in the motor or motor cabling.
Häufige Ursachen
- Motor cable insulation breakdown or short to ground.
- Motor winding fault or short to ground.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Inspect motor cable for damage, especially insulation, and continuity to ground.
- 2
Check motor for winding faults or insulation breakdown to ground.
- 3
Reinitialize the drive bus: Power Off / Power On.
- 4
Check the KSP module.
- 5
Check the KPP module.